Powdercoat | Remedial Work.jpg)
Should any remedial work be required the following steps should be followed
- Surface should be cleaned & degreased using a Cromadex degreaser
- Area to be coated should be abraded with 320/400 grade abrasive paper
- Area to be cleaned using a lint free tac rag
- Exposed metal area to have one thin coat of Cromadex 903 Two Pack Chromate Free etch primer applied & allowed to dry for one hour
- Apply by brush or spray one coat of Cromadex 600 or 800 line Two Pack Polyurethane Topcoat matched to correct shade & gloss level.